Strain Gage Data Logger
Up to 24/32 Channels, USB, Desktop
Description
This data logger includes the digitizer, signal conditioning, and sensor connectivity necessary to complete a 24-channel strain gage (or other bridge-type sensor) data-logging system with the plug-and-play ease of a USB connection to your computer.
Alternatively, you can use an M Series data acquisition device as the digitizer in your computer instead of the SCXI-1600. By doing this, you can add another SCXI-1520 and SCXI-1314 to your system and increase the number of strain gage channels to 32.
Please
consult with your sales representative for help in further configuring your application.
| Hardware |
| PCI-6221 | Use in place of the SCXI-1600 as the digitizer and to expand thermocouple channel count to 32. | Low-cost, 16-bit, 250 kS/s M Series multifunction I/O data acquisition board | 779066-01 | 1 |
| SHC68-68-EPM | Use this cable if selecting the PCI-6221 data acquisition device. | Noise-rejecting, shielded cable | 192061-01 | 1 |
| SCXI-1349 | This cable assembly is required when cabling from an SCXI chassis to a PCI data acquisition device. | Shielded cable assembly for connecting data acquisition board to chassis | 776574-491 | 1 |
| SCXI-1314T | Use in place of the SCXI-1314 when using TEDS strain gages. | Front-mounting terminal block with screw terminals for TEDS strain gage connections | 777687-14T | 1 |
| Software |
| LabVIEW Full Development System | Use LabVIEW instead of, or in combination with, NI VI Logger for customized intelligence. | Graphical programming language for developing customized applications | 776670-03 | 1 |
To order an alternative product, replace the part number and quantity from the recommended configuration in your shopping cart with the part number and quantity of the alternative product.